Supply Of Horizontal Sterilizer 250-300 Litres With Accessories At Hassan, Karnataka

Sterilizers Tender Posted on :  27 Feb, 2015
Tender Details:

supply of Horizontal Sterilizer 250-300 Litres with Accessories at Hassan

  • EMD

    :

    Rs. 30000/-

  • Quantity

    :

    1 Pieces

  • Notice Type

    :

    Domestic Tender Notice

  • Products

    :

    Sterilizers

View Similar Tenders
Participation in above Tender has been closed. View more Tenders below, or click the button above for Similar Tenders.
Important Dates

  • Tender Publish Date

    :

    2015-02-25

  • Document Submit Before

    :

    2015-03-17

  • Tender Due Date

    :

    2015-03-20

TENDER ALREADY EXPIRED

Hassan - Karnataka

  • Authority Name:Karnataka State Drugs Logistics And Warehousing Society
  • Address:No.1 Dr. Siddaiah Puranik Road, KHB Colony, Magadi Road, Bangalore 560 079, Hassan - Karnataka

» Recommended Tenders for Sterilizers

Supply Of Flash Sterilizer At Bhubaneswar

07-Mar-2019 Bhubaneshwar Orissa
Tenders Are Invited For Supply And Installation Of Flash Sterilizer (Technical Specification: 1) The Steriliser Should Be With A Chamber Size Of Approximately 16 X 16 X 36 And Approximate Capacity Should Be Around 150 Litres (5 Cu Ft). 2) The Chamber Should Be Double Walled Made Of Suitable Material (S.S.316L) Which Is Resistant To Corrosion And Gas. 3) To Minimize The Gas Deposit The Interior Of The Chamber Should Be Smoothly Finished 4) There Should Be Provision For Heating The Chamber Either With Strip Air Heater Or Hot Water Circulated Through A Coil Of Stainless Steel Around The Chamber To Maintain The Chamber Temperature Around 30 55 Degrees Centigrade. 5) The Chamber Shall Be Appropriately Insulated Against Heat Emission. 6) The Door Of The Steriliser Should Have A Quick Release Locking Arrangement, With Door Opening To The Sides 7) Suitable Safety Interlocking Arrangement Shall Be Provided For The Door So That The Sterilization Process Does Not Start Unless The Door Is Properly Locked In Position And Should Not Open During The Programme. 8) The Sterilizer Shall Be Provided With Suitable Vacuum Pump And Gas Trap To Separate And Evacuate The Gas. ) At Bhubaneswar
Quantity : 3 Unit
EMD : 25,000
Document Fees : 5,600
Notice Type : Domestic Tender Notice
Product / Services :Sterilizer
Doc Submit Before : 12-Apr-2019
Due Date : 15-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Ethylene Oxide Sterilizer At Dehradun

11-Mar-2019 Dehradun Uttarakhand
Tenders Are Invited For Supply Of Ethylene Oxide Sterilizer With Sealing Machine, Packing Material And Cartridge ( Specification -Suitable Denudation Pipette For Denudation Of Bovine Oocyte. Micropipetter With Comfort Grip With Sterile Tips MEA And LAL Tested, Suitable For Denudation Of Bovine Oocytes After The IVF Procedure . The Size Is 150 To 170 m Of Bovine Oocyte. Individually Packed Tips . Total Of 200 Tips Required. CE Conformity Certified And Provide Certificate In Original. Bidders Must Submit The Sole/exclusive Distributor Certificate Issued By The Manufacturer. Warranty: 2 Years. Must Provide Catalogue Number Of All Parts As Above.) At Dehradun
Quantity : 1 Unit
Tender Value : 10 Lakhs
EMD : 25,000
Document Fees : 180
Notice Type : Domestic Tender Notice
Product / Services :Ethylene Oxide Gas Sterilizer
Doc Sale Starts : 11-Mar-2019
Doc Sale Ends : 30-Mar-2019
Doc Submit Before : 30-Mar-2019
Due Date : 30-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Autoclave Rapid Sterilizer At Aligarh

13-Mar-2019 Aligarh Uttar Pradesh
Tenders Are Invited For Supply Of Autoclave Rapid Sterilizer ( Removable Stainless Steel Cassette, When Inserted Into The Insulated Steel Receptacle, Forms The Sterilization Chamber. Should Be Utilizing A Pressure Pulse Method Of Dynamic Air Removal And Also Designed With A Much Smaller Sterilization Chamber That Allows For A Faster Turnaround Time For Smaller Loads. Should Have Ultrafast 9 Minute Unwrapped Cycle And 17.5 Minute Wrapped Cycle. Should Be Single Use Water, Exceptional Instrument Turnover, Aseptic Transfer Of Instruments Directly To The Point Of Use And Reduced Instrument Investment. Should Have 15 Minute Dri-Tcc Drying Technology. ) At Aligarh
Quantity : 1 Unit
EMD : 16,000
Document Fees : 1,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Autoclave Sterilizer
Doc Submit Before : 30-Mar-2019
Due Date : 01-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Sterilizer Electric At Mandya

04-Mar-2019 Mandya Karnataka
Tenders Are Invited For Supply Of Sterilizer Electric (Should Be Ade Of High Quality Stainless Steel And Fitted With Good Quality Plastic Handle -220 V / 50 Hz -should Be Chemical Resistant - Size 20 X 8 X 8inches ) At Mandya
Quantity : 2 Unit
Tender Value : 6,000
Notice Type : Domestic Tender Notice
Product / Services :Electric Sterilizer
Doc Submit Before : 02-Apr-2019
Due Date : 03-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Autoclave Horizontal Rectangular Sterilizer At Bangalore

27-Feb-2019 Bangalore Karnataka
Tenders Are Invited For Supply Of Autoclave Horizontal Rectangular Sterilizer (Chamber Ss 316, Operating Pressure : 1.2 Kg/ Cm2 Working Temperature: Around 134oc. Chamber Volume 432 Ltrs. Dimension 600 Mm X 600 Mm X 1200 Mm, (w X H X D) Jacket Ss 316 Channelize Insulation Of Shell 100 Mm Insulation Covered With Ss 316 Outer Cover. Door Ss 316 Hinge Type Manual Door With Radial Locking Using Shooting Bolts, Should Have Pressure Locking Safety Facility. The Unlocking Is Possible Only When The Chamber Is Exhausted. Door Gasket Heat Resistance Silicon Door Gasket (1 No) In Built / Steam Generator Ss 316 With 36 Kw Heating Load, Safety Valves, Pressure Switches, Water Level Controller And Automatic Water Feeding System To Be Provided. (it Will Be Capable Of Producing The Required Steam To Operate A Horizontal Rectangular Sterilizer) Electrical Load 36 Kw On 3 Phase 4-wires, 400 - 440volts 50hz A.c. Supply Power Consumption/cycle 10 Kw/cycle Piping Ss 316 For Chamber / Jacket Mode Of Cycle Operation A Manual Cycle Should Be Operated Multi-port Operating Valve To Set And Select Different Cycles Of Operation Standard Features High Quality Silicon Gasket, Should Have An Air Pump, Pressure Control Switch, Should Have Cut Off For Overheating And Insufficient Water. Should Have The Facility To Cut Off The Power Supply To Heaters When The Set Pressure Is Achieved And Start Again Heating Element When Pressure Falls Below The Set Point. Vacuum Drying, Chamber Condensate Line With Steam Trap And Check Valve. Stainless Steel Perforated Trays. Closed Door Drying. Pressure Gauge, Compound Gauge, Dial Thermometer, Plug Screen, Steam Trap As A Standard Fitment With The Autoclave Equipment. System Including Heating Element Should Be Isi Marked. Should Be Hydraulic Tested Upto 2.5 Times Working Pressure. Should Have A Temperature Recorder) At Bangalore
Quantity : 2 Unit
EMD : 30,000
Notice Type : Domestic Tender Notice
Product / Services :Rectangular Sterilizer
Doc Sale Starts : 27-Feb-2019
Doc Submit Before : 27-Mar-2019
Due Date : 29-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Horizontal High Pressure Pressure Rectangular Sterilizer At Bhubaneswar

07-Mar-2019 Bhubaneshwar Orissa
Tenders Are Invited For Supply And Installation Of Horizontal High Pressure Pressure Rectangular Sterilizer ( Autoclave HP Horizontal GMDN Name: Autoclave HP Horizontal General 1 Use 1.1. Clinical Purpose: An Airtight Vessel For Heating And Sometimes Agitating Its Contents Under High Steam Pressure; Used For Sterilizing, With Moist Or Dry Heat At High Temperatures. 1.2. Used By Clinical Department/ward: CSSD Technical) ) At Bhubaneswar
Quantity : 1 Unit
EMD : 10,000
Document Fees : 5,600
Notice Type : Domestic Tender Notice
Product / Services :Sterilizer, Horizontal Autoclave
Doc Submit Before : 12-Apr-2019
Due Date : 15-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply And Installation Of ETO Sterilizer At Bhubaneswar

27-Feb-2019 Bhubaneshwar Orissa
Tenders Are Invited For Supply And Installation Of ETO Sterilizer (1. The ETO Gas Sterilizer Should Be Fully Automatic Type For Sterilization Of Heat Sensitive Goods Such As Anaesthetic Tubing And Other Plastic Disposable Materials Etc. 2. The Sterilization Chamber Should Be Double Walled, Corrosion And Gas Resistant Of Suitable Alloy. The Chamber Shall Be Insulated Against Heat Emission Specify The Mechanism Of Heat Insulation. 3. The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 4. The Sterilizer Door Shall Have A Quick Release Locking Arrangement, With Door Opening To The Sides. 5. Suitable Safety Interlocking Arrangement Shall Be Provided For The Door So That The Sterilization Process Does Not Start Unless The Door Is Properly Locked In Position And During The Program Run It Should Not Open If There Is Any Residual Gas. 6. The Sterilizer Shall Be Provided With Suitable Mechanism To Separate And Evacuate The Gas Specify The Mechanism. 7. The ETO Sterilizer Should Be Able To Operate For The Minimum Essential Following Cycles Programs: A. Sterilization Cycle For Heat Sensitive Objects That Ensure Temperature From 40-55 C With Subsequent Aeration For Protection Of The Operating Personnel. B. Aeration Cycle/program To Extract Residual Gas Out Of The Sterilized Objects After Each Sterilization Cycle. C. Automatic Chamber Evacuation Cycle With Subsequent Venting Before Releasing The Door Lock For Opening. Thereby Prohibiting Exposure Of The Operating Personnel By Gas Dissolving From The Chamber Walls During Shutdown Period. D. Appropriate Pollution Control Device For Safe Disposal Of E.O Like Gas Disposal Management / Catalytic Converter Provision To Be A Per Local/ International Pollution Control Norms, If Any. 8. Capacity: Should Have One-time Loading Of 24-33 Cu. Ft. With Capacity To Process 36-48 Fu. Ft. /24hr. Firm Should Clearly State Cycle Time (Time From Start To Finish Including Aeration Time) So That Capacity To Process Total Load In 24 Hr Can Be Calculated.) At Bhubaneswar
Quantity : 5 Unit
EMD : 1.50 Lakhs
Document Fees : 5,600
Notice Type : Domestic Tender Notice
Product / Services :Ethylene Oxide Gas Sterilizer
Doc Submit Before : 28-Mar-2019
Due Date : 30-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply & Installation Of Biomedical Waste Horizontal Sterilizer At Bhubaneswar

04-Mar-2019 Bhubaneshwar Orissa
Tenders Are Invited For Supply & Installation, Commissioning Of Biomedical Waste Horizontal Sterilizer ( 1.1 Clinical Purpose Waste Sterilizer Should Be Designed For Sterilization Of Regulated Biomedical Waste Generated From Hospital For Destruction Of Bacteria And Related Organism (Spores) And Dispose Of All Infectious Waste In An Efficient, Safe, Environment Friendly And Cost Effective Manner In Compliance With The Various Regulations And Guide Lines. 1.2 Overview Of Functional Requirement The Sterilizer Should Be Capable Of Autoclaving The Following Categories: 1. Waste Sharps, 2. Highly Infectious Waste Like Blood Bags, Lab Culture, Bio-technology Waste. 3. Discarded Infected Items 5. Soiled Waste Like Infected Cotton, Swab Pieces Etc. ) At Bhubaneswar
Quantity : 6 Unit
EMD : 1.20 Lakhs
Document Fees : 5,600
Notice Type : Domestic Tender Notice
Product / Services :Bio Waste Sterilizer
Doc Submit Before : 10-Apr-2019
Due Date : 15-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Plasma Sterilizer At Chandigarh

20-Feb-2019 Chandigarh Chandigarh
Tenders Are Invited For Supply Of Plasma Sterilizer At Chandigarh
Quantity : 4 Unit
EMD : 3.20 Lakhs
Document Fees : 200
Notice Type : Domestic Tender Notice
Product / Services :Plasma Sterilizer
Due Date : 28-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Flash Autoclave Sterilizer At Bangalore

27-Feb-2019 Bangalore Karnataka
Tenders Are Invited For Supply Of Flash Autoclave Sterilizer (01 Flash Autoclave Horizontal, High Pressure Sterilizer, Cylindrical Type With Hinged Single Door, Dual Pressure Electric Heated Manual Cycle Operated : Model-16hs/e/sd/dp Chamber Ss 316 Size : 400mm Dia.x 600mm Depth Operating Pressure : 1.2 2.1kg/cm Working Temperature: 121 - 134 C Sterilization Time 121 C 20 Minute, Total Cycle Time 60-70 Mint. 134 C 7 Minute. Total Cycle Time 30-40 Mint. Chamber Ss 316 Chamber Volume 79 Ltrs Jacket B.q. Steel. Insulation Of Shell 100 Mm Insulation Covered With Ss 316 Outer Cover. Door A Hinge Type Manual Single Door With Radial Locking Using Shooting Bolts, Having Pressure Locking Safety Facility. The Unlocking Is Possible Only When The Chamber Is Exhausted) At Bangalore
Quantity : 1 Unit
EMD : 11,250
Notice Type : Domestic Tender Notice
Product / Services :Flash Autoclave
Doc Sale Starts : 27-Feb-2019
Doc Submit Before : 27-Mar-2019
Due Date : 29-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information