Supply Of Detector Tubes For Compressed Air (i) Detector Tube For Water Vapour (Ii) Detector Tube For Oil Mist, Maharashtra

Gas Detector Tubes Tender Posted on :  27 Dec, 2018
Tender Details:

Supply Of Detector Tubes For Compressed Air (i) Detector Tube For Water Vapour (Ii) Detector Tube For Oil Mist

  • Authority Type

    :

    Public Sector

  • Notice Type

    :

    Domestic Tender-Notice

  • Products

    :

    Gas Detector Tubes

View Similar Tenders
Participation in above Tender has been closed. View more Tenders below, or click the button above for Similar Tenders.
Important Dates

  • Tender Publish Date

    :

    20-DEC-18

  • Document Sale Starts

    :

    20-DEC-18

  • Document Sale Ends

    :

    21-JAN-19

  • Document Submit Before

    :

    21-JAN-19

  • Tender Due Date

    :

    21-JAN-19

TENDER ALREADY EXPIRED

Mumbai City - Maharashtra

  • Address:Mumbai City, Maharashtra, Mumbai City - Maharashtra
  • Email:chairman@dae.gov.in

» Recommended Tenders for Gas Detector Tubes

Supply Of Gas Chromatography System At New Delhi

11-Feb-2019 New Delhi Delhi
Tenders Are Invited For Supply Of Gas Chromatography System ( 1. Injector Minimum 2 Inlets. Gas Sampling Valve With The Provision For Inter-changeable Manual And Automatic Injection Of Gas. Heating Range Up To 200 C Or Higher. Automatic Sampling Software Controlled. 2. Column Molecular Sieve (1/8 Dia., Minimum 6 Ft Length). SS Body With Inlet/outlet Connectors. Quantity: 2 Nos. 3. Column Oven Temperature Range, Up To 300 C Or Higher. Programmer: Ramp Rate Range 5 C/min To 15 C/min Or Higher. 4. Detector Thermal Conductivity Detector (TCD) Detection Limit Of TCD: 10 Ppm Of H2or Better. Dynamic Range : 105 Temperature: Up To 300 C Or Higher. 5. Software All Necessary Software To Run The Instrument, Data Collection And Analysis With Necessary Libraries. 6. Accessories Gas Tight Syringe, 1 Ml (2 Nos.). Suitable PC. Argon Gas Cylinder (Grade 1), Gas Regulator And Gas Panels For Gas. Moisture And Oil Traps. Tubings And Fittings For Argon Gas Cylinder And Panels For Smooth Installation ) At New Delhi
Authority Type : Technical Institutes
Notice Type : Domestic Tender Notice
Product / Services :Gas Chromatography Machine
Doc Sale Starts : 06-Feb-2019
Doc Sale Ends : 27-Feb-2019
Doc Submit Before : 27-Feb-2019
Due Date : 28-Feb-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply And Installation Of One CHNSO Analyser With Accessories At New Delhi

29-Jan-2019 New Delhi Delhi
Tenders Are Invited For Supply And Installation Of One CHNSO Analyser With Accessories ( Specification :01 Fully Automated PC Controlled CHNS/O Analyzer For Solid (including Soil, Sediments, Plants, Organic Particulate Collected On Filters, Fertilizer), Liquid And Viscous Samples. The Analyzer Should Provide Combustion Of The Samples Followed By Reduction, Trapping, Gas Separation And Detection Of The Products By Temperature Stabilized Thermal Conductivity Detector (TCD) For CHNS/O Analysis With CHN, CHNS, And O Modes. Oxygen Analysis Kit Must Also Be Quoted. 02 The Analyzer Must Have Dual Furnaces For Combustion And Reduction With Separate Reactor Tubes. There Should Be Facility In The Instrument To Shift From One Furnace To Another Furnace Automatically Through Software Without Manual Intervention Enabling For Simultaneous Analysis Of CHNS And O Analysis. There Should Be Provision For Individual Temperature Control For Combustion And Reduction. The Furnace Temperature Should Be 1100C Or More And Sample Temperature During Combustion Should Reach 1700C Or More To Ensure Complete Combustion. Pyrolysis (determination Of Oxygen) Furnace Temperature Should Be 1000C Or Better. Ash Finger (or Similar Technique) A Standard Part, Should Be Supplied With The Instrument To Collect The Ash Of The Sample. 03 Analyzer Should Have Auto Sampler With Capacity Of Minimum 50 Samples Or More. 04 Set Of Consumables For 3000 Solid And Liquid CHNS/O Samples 05 Data Management Software With Original License To Collect And Store Data, Perform Advanced Calculations (elemental Ratios (i.e. H/C, N/C, S/C, C/N, Simplest Empirical Formula), Recalculate A Result, Run Queries (searches) Generate Statistics, Create Reports And Archive Data) At New Delhi
EMD : 25,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Hydrogen Analyzer, Carbon Analyzer
Doc Sale Starts : 29-Jan-2019
Doc Sale Ends : 18-Feb-2019
Doc Submit Before : 18-Feb-2019
Due Date : 19-Feb-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Laboratory Instruments At Jhalawar

08-Feb-2019 Jhalawar Rajasthan
Tenders Are Invited For Supply Of Laboratory Instruments (1 Turbidity Meter (Benchtop) Range 0-1000 NTU In 4 Range (Automatic) (a) 0-1 NTU (b) 0-10 NTU (c) 0-100 NTU (d) 0-1000 NTU Accuracy + 1.5% Of FSD In 0-500 NTU + 2% Of FSD In 500-1000 NTU Repeatability: + 1% If FS (Std.) Source: LED Detector: Photodiode Display: 2 Line 16 Ch. LCD Calibration: Formazine Standard Solution Data Storage: Calibration & Data Stored In Memory Printer Port: Epson Compatible 80 Column Dot Matrix Power: 230 Volts + 10%, 50Hz Dimensions: 160 (W) X 200 (D) X 100 (H) Mm Weight: 1.5 Kg (Approx) Accessories: Flat Bottom Test Tubes- (25mm ) 4 Nos. & Light Shield, 4-extra Lamp, Formazine Standard Solution (Make: SYSTRONIC /TOSHNIWAL/ HACH/HANNA) Qty 01 Unit 2 PH Meter (Benchtop) Range: 0-14 PH & 0-1999 MV Accuracy: 0.01 PH 1 Digit 1 MV 1 Digit Resolution: PH: 0.01 PH MV: 1mV Display: LCD, 2 Line, 20- Character Alphanumeric Annunciation: Individual LED With Keys For Calibration, PH, ABS MV, REL MV And Print Standard Buffer: 4.0, 7.0 And 9.2 Data Storage: 80 Readings Power Supply: 220 Volts + 10% Essential Accessory: (1) PH Electrode (6 Nos.) (2) Temperature Probe. (4 Nos.) (3) Electrode Stand & Clamp (2 Nos.) (4) Buffer Tablets (10No.each ) Of PH 4.0, 7.0 And 9.2 (Make: TOSHNIWAL (TOSHCON)/SYSTRONICS/WTW) 4.0, 7.0 And 9.2 Qty 02 Unit 3 Conductivity Meter (Benchtop) Micro Controller Based Conductivity Meter With Temp. Probe Source Frequency: 100 Hz Or 1 KHz Automatically Selected Range Selection: Automatic Conductivity Range: 0 s To 2 s With 0.01 Cell Constant 0 s To 20 s With 0.1 Cell Constant 0 S To 200 MS With 1.0 Cell Constant (5 Decadic Ranges) TDS: 0 Ppm To 20 Ppt With 0.1 Cell Constant And 0 Ppm To 200 Ppt With 1 Cell Constant In 5 Decadic Ranges Temperature: 0 C To 100 C (Auto/ Manual) Display: 7 Digits, 7 Segment LEDs ( 3 Digits For Temp./ 4 Digits For Conductivity/ TDS ) Resolution: 0.001 s Is Lowest Rang With Cell Constant Of 0.01 Conductivity: 0.01 s Is Lowest Rang With Cell Constant Of 0.1 TDS: 0.01 Ppm In Lowest Range With Cell Constant Of 0.1 Temperature: 0 C -100 C ( Auto/ Manual ) Accuracy: + 0.2 C + 1 Digit Conductivity/ TDS: + 1% Of F.s. + 1 Digit Temperature: 1 C+ 1 Digit Storage: Up To 1000 Samples Cond. Cell Compensation: 0.02 Cell Constant: 0.009 To 0.01 0.1 Cell Constant: 0.09 To 0.11 1 Cell Constant: 0.9 To 1.1 TDS Factor: 0 To 1.00 Cond. Temp. Range: 0.0 To 10.0% Per C Temperature Range: 0 To 100 C Temperature Sensor: PT- 100 Power: 230 V+ 10% 50 Hz Dimensions: 210 (W) X 220 (D) X 105 (H) Mm Wight: 1.7 Kg (Approx) Accessories: (1) 1 Cell Constant Cell (3 No) (2) 0.1 Cell Constant Cell (3 No) (3) 0.01 Cell Constant Cell (3 No) (4) Temperature Probe (Pt. 100 Sensor) (3No) (5) Clamp & Stand (6) Standard Conductivity Solution Bottle (3 No) 1413 S/cm 500 Ml KCl/NaCl 1000 S/cm 500 Ml KCl/NaCl 147 S/cm 500 Ml KCl/NaCl (Make: TOSHNIWAL (TOSHCON)/SYSTRONICS/WTW/ HACH) Qty 02 Unit 4 Portable Hydrogen Purity Meter Measuring Range & Gas Generator Purity Mode: 0-100.00% H2 In Air Generator Purge Model: 0-100.0 H2 In CO2 0-100.0 Air In CO2 Minimum Resolution: 0.1% Degree Of Accuracy: + 0.1%of Full Scale Read Out: Digital Graphical Display Sampling Mode: Sampling Plug - In Detection Principle: Thermal Conductivity (Katherometer) Response Time: Less Than 10 Seconds Warm Up Time: 10 Seconds Application Data Environmental Temperature Range: 20 To 50C (-4 To 122 F) Sample Inlet Pressure: 10 To 25 PSIA, 10 PSIG Maximum Sample Flow Rate: 0.1 - 10 L/min (0.2 To 20 Scfh) Flow Meter: In Built. Working Temperature: 0 60C Electrical & Communications Input Voltage: 100-240 VAC, 50-60 HZ Standard Electrical Storage: 12- Volt, Sealed Lead - Acid Battery Approx. 8 Hours Usage Time Per Charge Current: 0, 5 A @ 120 VAC During Recharging Alarms: Two Levels (selectable Range) Warranty: Two Year (Make: ENDY / NOVA/ VASTHI) Qty 01 Unit 5 Muffle Furnace Internal Size: (H X W X D) 6X6X12 Inches Max. Operating Temperature: 1200 Deg Cent. Cr/Al/Pt/Platinum Rhodium
Tender Value : 7.08 Lakhs
EMD : 14,160
Document Fees : 236
Authority Type : State Govt
Notice Type : Domestic Tender Notice
Product / Services :Laboratory Instruments, Conductivity Meter, PH Meter
Doc Sale Starts : 08-Feb-2019
Doc Sale Ends : 21-Feb-2019
Doc Submit Before : 21-Feb-2019
Due Date : 21-Feb-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information