Supply Of Autoclave Sterilizer At Palode, Kerala

Autoclave Sterilizer Tender Posted on :  11 Jan, 2019
Tender Details:

Tenders Are Invited For Supply Of Autoclave (Sterilizer), ( Semi Automatic Horizontal Steam Rectangular (tissue Culture), The Autoclave Should Have Outer Chamber, Inner Chamber, Boiler, Lid And Jacket All Made Of Thick Ss 304/316 Grade, Able To Sterilize 400-500 Tissue Culture Bottles (pl Quotes Each Model Separately.) Pressure And Temperature Safety Controls/ Displays (preferably Digital) Auto Cut Off System, Separate Pressure Gauges For Boiler And Chamber, Alarm Facility, Self Locking Door, Operating Temperature 1210c At 15psi Pressure (1.2kg/cm Sq) The Hydraulically Tested (minimum 2.5 Kg/cm2/35psi) Autoclave Should Be Having Friendly Control Panel, Dimension Internal: Approximately 60-80cm Height X 60 -80cm Width X 110-130cm Length (pl Quote Each Model Separately), Autoclave Loading /unloading Carriage, Trolley For Ease Loading And Unloading ) At Palode

  • Tender Value

    :

    Rs. 13 Lakhs/-

  • EMD

    :

    Rs. 13000 /-

  • Document Fees

    :

    Rs. 2,240/-

  • Quantity

    :

    1 Unit

  • Notice Type

    :

    Domestic Tender Notice

  • Products

    :

    Autoclave Sterilizer

Important Dates

  • Tender Publish Date

    :

    11-JAN-19

  • Document Sale Starts

    :

    11-JAN-19

  • Document Sale Ends

    :

    28-JAN-19

  • Document Submit Before

    :

    28-JAN-19

  • Tender Due Date

    :

    31-JAN-19

    11  Days left

Due on: 31 Jan, 2019

Palode - Kerala

Additional Details Available on Purchase:

  • Publication document  Authority Details

» Recommended Tenders for Autoclave Sterilizer

Supply Of Autoclaves For Hand Piece Sterilization At Bhubaneswar

09-Jan-2019 Bhubaneswar Orissa
Tenders Are Invited For Supply , Installation & Commissioning Of Autoclaves For Hand Piece Sterilization (.Machine Dimensions (minimum): Length: 48 Cm, Width: 42 Cm, Height: 15 Cm .Cassette Size (External) (minimum): Length: 42 Cm, Width: 19.5 Cm Height: 4 Cm .Cassette Size (Internal): Length: 28 Cm To 30 Cm, Width: 18 Cm T..o 20 Cm, Height: 4 Cm To 6 Cm .Sterilisation Chamber Volume: 5L (minimum) .Reservoir Volume: 4.0L .Clearance Required: Top: 50 Mm .Sides: 50 Mm, Back: 50 Mm, Front: 48 Cm .Clearance Required To Remove Cassette: 48 Cm To 50 Cm .Minimum Charge In The Water Reservoir: 550 Ml .PRV Value (pressure Relief Valve): 3 BAR .Operating Electrical Rating: 220 - 240 V, 50Hz .Protection Class: I I .Protection: Covered .Ambient Operating Temperature: 5C - 40C .Sound Levels: Mean - 56 DB Mean) At Bhubaneswar
Quantity : 2 Unit
EMD : 5,000
Document Fees : 5,600
Notice Type : Domestic Tender Notice
Product / Services :Autoclaves
Doc Submit Before : 11-Feb-2019
Due Date : 16-Feb-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Double Door Steam Sterilizer- Automatic At Delhi

Yesterday Delhi Delhi
Tenders Are Invited For Supply Installation And Commissioning Of Double Door Steam Sterilizer- Automatic ( Microprocessor Control Steam Based, Purely Dedicated For CSSD Of Running Hospital (Autoclaving Of OT & Hospital Product) To Cater Sterile Services Of Deptt. Minimal Consumption Of Water And Energy. Microprocessor Based Control Panel Which Control All The Function Of Sterilization Automatically With Pneumatic Valves And Fittings. Chamber Size Approx. 600x900x1500mm Capacity Approx. 800-850 Lt. Electric Load Of At Least 36 Kw For Heater. Should Be Double Door, Steam Jacketed, Suitable For Operation On Electricity. Chamber Should Be Hydraulically Tested To Two Times The Working Pressure. Normal Working Pressure Should Be 1.2kg/cm2 At 121C And 2.1 Kg/cm2 At Around 134C. Should Have Water Ring Vacuum Pump To Create Vacuum For Evacuation Of The Air From Chamber. Chamber And Doors Would Be Of SS A ISI 316 Quality. Chamber Should Be Covered With Glass Wool Insulation And Cladded With Painted Steel Sheet. Chamber Should Be ISI/BIS Marked As Per IS: 3829. Door Should Be Provided With Gasket Silicon Leak Proof Good Quality Material. Door Should Be On Hinge For Self Alignment. Door Should Have One Automatic And Manual Lock. The Automatic Lock Would Operate At Pressure In Chamber Of 0.37kg/cm2. The Unit Should Be Fully Automatic With At Least 5 Preselected Programs Including Bowik Test And Leak Test. Should Have 2 Mechanical Ejectors. Should Have Self Sterilizing Vacuum Drier. Should Have Safety Valve Spring Loaded And Vacuum Breaker. Should Have Pressure Gauge. Should Have Dial Thermometer And Screen Plug For Chamber Discharge Live. Should Have SS Electric Boiler Under The Shell With Interconnecting Steam Pipes, The Boiler Should Have 36 Kw Immersion Heaters Mounted On SS Plate And Electric Control Would Comprise Of Air Break Contractor, Pressure Controller, Low Water Protection With Audiovisual Alarm. Th Boiler Should Have Gauge Glass Assembly With Glass Tube With Protector, Water Drain And Water Inlet Valves. The Unit Should Be Micro Processor Controlled For Controlling Entire Cycle Of Sterilization And Steam Pulsing Automatically Through Water Ring Vacuum Pump. In 300 Bedded Multi- Specialty Hospital) At Delhi
Quantity : 1 Unit
EMD : 50,000
Authority Type : Govt Hospital
Notice Type : Domestic Tender Notice
Product / Services :Steam Sterilizers
Doc Submit Before : 07-Feb-2019
Due Date : 07-Feb-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Autoclave (A) At Raipur

14-Jan-2019 Raipur Chhattisgarh
Tenders Are Invited For Supply Installation And Commissioning Of Autoclave (A) ( 1. It Should Be Vertical Type 2. Maximum Temperature Should Be 123oC 3. Accuracy Of Temperature 0.5 OC At 121 OC 4. Pressure Maximum Should Be Up To 0.12 Mpa 5. Fully Automatic Sterilization Process And Microprocessor PID Based Control Automatic Start/stop Timer, Dual LED Displays Temperature And Remaining Time, Auto-tuning Function And Sensor Should Be Class A Pt-100 6. Safety Door Inter-lock , Safety Door System Integrated With Over Temperature Cut Off, Over Pressure Cut Off, Over Current Cut Off 7. Lid, Top Plate And Chamber Must Be Stainless Steel 304 Along With Minimum Two Service Basket-stainless To Protect From Corrosion By Water And Steam 8. Body Should Be Epoxy Powder Coated 9. Inner Chamber Volume Should Be 60 To 90 Litres 10. Power Plug Should Be CEE 7/7 Schuko Or Equivalent 11. Special Plated Heating Element Should Be Resistant To Dry-burn, Corrosion And Guarantee Long Life In Repeated Use 12. Steam Collection Bottles Removes Most Of Steam Generated During Operation 13. Equipped With Drain Valve For Cleaning And Changing With Fresh Water 14. It Should Have High Pressure And Temperature Resistant Silicone Gasket, Built-in Analog Pressure Gauge, Manual Pressure Release Valve, Caster For Easy Transport And Manual Pressure Release Valve For Emergency ) At Raipur
Quantity : 1 Unit
EMD : 3,000
Document Fees : 1,000
Notice Type : Domestic Tender Notice
Product / Services :Autoclaves
Doc Submit Before : 28-Jan-2019
Due Date : 28-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Large Autoclave Machine At Raipur

12-Jan-2019 Raipur Chhattisgarh
Tenders Are Invited For Supply, Installation, Testing, Commissioning And Training Of Large Autoclave Machine (Autoclave Single Lever With Advanced Features & Drying Front Loading 300x500mm 35 Liter Or 400 X600mm 75 Liter User Friendly Lid Locking Single Level Lock . Lid Switch Ensures Proper Lid Locking . Lid Interlock For Residual Pressure . Sterilizing , Exhaust Of Water & Steam , Drying Are Fully Automatic . Steam Recondenses To Inbuilt Reservoir Which Allows It To Be Kept Inside AC Room . Requires A Sterlizing Time Of Just 7 Minutes At 134C (instead Of 20 Minutes At 121C) Result Reproducible Because Full Cycle Is Automatic Requiring No Human Intervention Programmable Logic Control With Auto Water Fill & Drying . Microprocessor Based Controller With Following Parameters Programmable By User . (A) Strelizer Time : Up To 99 Minutes (B) Sterlizer Temperature : Up To 134 C (C) Drying Time : Up To 99 Minutes With Spare Gasket Optional Accessories For The Above : Positive Pulsing Air Ballast With Filter (Post Sterlisation) Pre & Post Vacumm) At Raipur
EMD : 4,920
Authority Type : State Govt
Notice Type : Domestic Tender Notice
Product / Services :Autoclaves
Doc Submit Before : 18-Jan-2019
Due Date : 18-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Table Top Autoclave At Indira Nagar

08-Jan-2019 Indira Nagar Karnataka
Tenders Are Invited For Supply Of Table Top Autoclave (Type: Table Top Or Bench Top Steam Sterilizer Sterilizer Chamber Capacity (usable Volume) 23.0 - 25.0 Or Higher Type Of Cycle Processes Available: B-process, N- Process Sterilizer Chamber Type Rectangular Sterilizer Chamber Material SS 316 Or Better Grade Steel Working Pressure Of Chamber 2.2 Design Pressure Of Chamber 3.8) At Indira Nagar
Quantity : 2 Unit
Notice Type : Domestic Tender Notice
Product / Services :Autoclaves
Doc Submit Before : 21-Jan-2019
Due Date : 21-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of High Speed Sterilizer At New Delhi

20-Nov-2018 New Delhi Delhi
Tenders Are Invited For Supply Of High Speed Sterilizer (1.1 Autoclaves Are Required For Sterilizing An Object In High Temperature And High Pressure Steam. 2.1 High Speed Horizontal Cylindrical Steam Sterilizers Pressure Type Designed To Operate On Steam From Steam Generator 2.2 It Should Provide High Speed Sterilization 3 Technical Specifications 3.1 Strong Argon.arc Welded Chamber 3.2 Inner Chamber Built Of AISI 316 Grade Of Stainless Steel, Outer Cover Of AISI 304 Grade Stainless Steel And Jacket Of BQ Steel 3, 3 Chamber Depth Around 1000 Mm 3.4 Nominal Capacity App 150 Litres 3.5 Pressure Range: More Than 2 Kg. /cm2 (133-134 Deg C) To Reduce Cycle Time Substantially 3.6 Should Have Been Tested For Twice The Working Pressure 3.7 Self Locking Safety Door Under Pressure 3.8 Heat Resistant EPDM Door Gasket 3.9 Centralised Control Point With Multiport Valve Control For The Entire Cycle Of Operation 3.1 Cycle With Pre Vacuum Option ) At New Delhi
Quantity : 01 Unit
EMD : 8,000
Document Fees : 500
Authority Type : Govt Hospital
Notice Type : Domestic Tender Notice
Product / Services :Sterilizer
Doc Submit Before : 28-Jan-2019
Due Date : 28-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Double Door Autoclave At Raipur

02-Jan-2019 Raipur Chhattisgarh
Tenders Are Invited For Supply, Installation, Testing, Commissioning And Training Of Double Door Autoclave (The Autoclave Shall Be Double Door, Rectangular, Steam Operated, High Pressure High Vacuum, Suitable For Horizontal Loading Of Waste. The Autoclave Shall Be With Bio-seal Design. The Chamber Size Shall Be Approximately 600 Mm X 600 Mm X 1200 Mm. The Autoclave Shall Be Free Standing Type. The Autoclave Shall Be PLC Controlled, Programmable And Shall Be Loaded With Different Pre-programmed Decontamination And Sterilization Cycles. The Autoclave Chamber Shall Be Constructed Of Heavy Duty SS Of 316 (min. 6 Mm Thickness) With Full Argon Welding. The Chamber Material And Construction Shall Meet ASME Standards For Unfired Vessels. The Chamber Shall Be Duly Reinforced With The Help Of Carbon Steel. Doors And Jacket Shall Be Constructed Of Stainless Steel Sheet Of 304 Grade (min. 5 Mm Thickness). Doors Must Be Provided With Automatic Safety Locking And Unlocking Devices. All Doors Shall Be With Gasket To Ensure A High Temperature Seal. Chamber And Doors Shall Be Designed For Working Under Positive Pressures Up To 31 Psig At Temperature Up To 135o C. The Autoclave Shall Be Insulated With 50 Mm Thick Resin Bonded Glass Wool To Minimize Heat Loss And Restrict The Skin Temperature Within Reasonable Limits So As Not To Cause Burn Due To Accidental Touch. Pipes And Fittings Shall Be Of Stainless Steel And Bronze. Key Locked Main Power Switch Should Be Provided For Additional Safety And Security. The Autoclave Shall Be Provided With A Vacuum Pump Mounted On A Mini Skid. The Vacuum Line Shall Be Provided With An Absolute Vent Filter Cartridge (0.22 Micron Or Better) For Safe Vent And Shall Allow In-Situ Decontamination Of Filter For Safe Change When The Filter Is To Be Accessed. The Autoclave Control System Shall Be PLC Controlled, Programmable And Shall Allow Up-to Six Pre-programmed Cycles. The Logic Of Preprogrammed Cycles Shall Be Developed As Per The Requirement Of The End Users. The In-built Steam Generator Shall Be Provided With The Autoclave. The Steam Generator Shall Be Fabricated From SS 316 L (16 Gauge) With Industrial Immersion Heater Of Reputed Make. The Immersion Heaters Shall Be Heavy Duty Type In Stainless Steel Construction. The Heater Shall Be Of Suitable Capacity So As To Achieve The Required Operating Temperature And Pressure In About 30 Minutes To Start The Autoclave Cycle And Should Be Capable Of Maintaining The Pressure And Temperature Thereafter During Various Load Cycles Of The Autoclave.) At Raipur
Quantity : 1 Unit
EMD : 2,470
Authority Type : State Govt
Notice Type : Domestic Tender Notice
Product / Services :Autoclaves
Doc Submit Before : 23-Jan-2019
Due Date : 24-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Programmable Horizontal Autoclave For Bio Medical Waste At New Delhi

20-Nov-2018 New Delhi Delhi
Tenders Are Invited For Supply Of Programmable Horizontal Autoclave For Bio Medical Waste (1. Should Meet Requirements Of Disinfection/Sterilization Of Bio Medical Waste. 2. Should Have A Chamber Capacity Between 450-500 Litres. Depth Of The Chamber Should Preferably Be Less Than
Quantity : 01 Unit
EMD : 90,000
Document Fees : 500
Authority Type : Govt Hospital
Notice Type : Domestic Tender Notice
Product / Services :Horizontal Autoclave
Doc Submit Before : 28-Jan-2019
Due Date : 28-Jan-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information