Supply And Installation Of TKN Analyser Semi-Automatic With Aluminium Block Digester At Dehradun, Uttarakhand

Semi Auto Analyser Tender Posted on :  15 Apr, 2019
Tender Details:

Tenders Are Invited For Supply And Installation Of TKN Analyser Semi-Automatic With Aluminium Block Digester ( Sample Volume Should Cover 1 To 15 Ml Measuring Range Should Cover 1 To 150 Mg-nitrogen Reproducibility Approx. +/-1% Semi-automatic Distillation And Titration Unit Distillation Semi-automatic Distillation Time Less Than 10 Min. Titration Manual Calculation Manual Digestion Unit Digestion Capacity Approx. 300 Ml X 10 Pcs Temp Controller Temperature Setting Range Should Cover 0 To 600 Degree C Acid Mist Scrubber Gas Washing NaOH And Water Chemical Diaphragm Pump Approx. 28 Liter/min .Manufacturer's Standard Accessories 1 Set Uninterrupted Power Supply System Single Phase, On-line With Maintenance Free Battery; 15 Min Back Up; Capacity Suitable For The Entire System. Digestion Tube Approx 300ml 10 Pcs Catalyzer For Digestion 1000 Pcs. 6. SPARE PARTS & CONSUMABLE Digestion Tube Approx 300ml 40 Pcs Teflon Ring. 10 Pcs 1 Set Sealed Clip. 10 Pcs 1 Set Manifold 1 Set Steam Inlet Tube 3 Pcs Rubber Cone. 5 Pcs 1 Set Distillation Head 1 Pc ) At Dehradun, Roorkee, Kashipur, Ghaziabad, Bijnour, Raibareilly, Kanpur, Prayagraj, Varanasi, Bulandshahr, Luckno W, Patna, Barauni, Ranchi, Dumka, Kolkata, Barrackpur

  • EMD

    :

    Rs. 2.04 Lakhs/-

  • Quantity

    :

    17 Unit

  • Notice Type

    :

    Tender Notice

  • Products

    :

    Semi Auto Analyser

View Similar Tenders
Participation in above Tender has been closed. View more Tenders below, or click the button above for Similar Tenders.
Important Dates

  • Tender Publish Date

    :

    15-APR-19

  • Document Sale Starts

    :

    25-MAR-19

  • Document Submit Before

    :

    23-APR-19

  • Tender Due Date

    :

    23-APR-19

TENDER ALREADY EXPIRED

Dehradun - Uttarakhand

  • Contact no.:+91-1123072900
  • Address:1st Floor, Major Dhyan Chand National Stadium India Gate, New Delhi - 110002, Dehradun - Uttarakhand
  • Email:nmcgtenders@gmail.com

» Recommended Tenders for Semi Auto Analyser

Supply Of Nephlometry Semi Auto Analyser At Gurugram

8 hrs ago Gurugram Haryana
Tenders Are Invited For Supply, Installation, Testing And Commissioning Of Nephlometry Semi Auto Analyser And Accessories Diagnostic Lab Facility At Gurugram
Tender Value : 5 Lakhs
EMD : 10,000
Document Fees : 1,120
Authority Type : Public Sector
Notice Type : Domestic Tender Notice
Product / Services :Semi Auto Analyser
Doc Sale Starts : 20-May-2019
Doc Sale Ends : 03-Jun-2019
Doc Submit Before : 03-Jun-2019
Due Date : 06-Jun-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Coagulation Semi Auto Analyser At Gurugram

9 hrs ago Gurugram Haryana
Tenders Are Invited For Supply, Installation, Testing And Commissioning Of Coagulation Semi Auto Analyser With Pippette And Accessories At Diagnostic Lab Facility At Gurugram
Tender Value : 5 Lakhs
EMD : 10,000
Document Fees : 1,120
Authority Type : Public Sector
Notice Type : Domestic Tender Notice
Product / Services :Semi Auto Analyser, Pipette, Diagnostic Lab
Doc Sale Starts : 20-May-2019
Doc Sale Ends : 03-Jun-2019
Doc Submit Before : 03-Jun-2019
Due Date : 06-Jun-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Semi Automatic Bio Chemistry Analyser At Bahraich

17-May-2019 Bahraich Uttar Pradesh
Tenders Are Invited For Supply Of Semi Automatic Bio Chemistry Analyser (Configuration & Physical Characteristics Usage: The Equipment; Semi Automatic Bio Chemistry Analyser Is Used For Measurements Of Bio-chemistry Tests, Using Wet Chemistry Reagent(s) And Have Ability To Use External Cuvettes And Integrated Flow Cell. Semi Automated Bio Chemistry Analyser Is With Built In Software For The Calculation And ) At Bahraich
Quantity : 2 Unit
Notice Type : Domestic Tender Notice
Product / Services :Chemistry Analyzers
Doc Submit Before : 24-May-2019
Due Date : 24-May-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Auto Analyzer At Ranchi

30-Apr-2019 Ranchi Jharkhand
Tenders Are Invited For Supply Of Auto Analyzer For MRU (Auto Analyzer 1. Fully Automated Random Access Chemistry Analyzer Bench Top With Stat Sample Priority. 2. Through Put Of 180-200 Photometric Tests / Hour, 200- 270 Ise Test/ Hour. 3. Bar Code System For Detection Of Sample Ii) And Reagent. 4. 40 Positions For Samples And 40 Reagents Position With Onboard Cooling For Reagent. 5. Sample Volume 2-35 1(0.1 I Increments) And Reagent Volume Of 20-400 I. 6. Separate Pipette For Reagent And Sample. 7. Pre-dilution And Automatic Re-assay With Diluted Sample / Reduced/ Increased Sample Volume Should Be There. 8. Continuous Sample Loading Provision. 9. Serum Plasma, Urine, Csf And Superoantscan Be Processed In The Machine. 10. Sample Pipette With Liquid Level Sensor And Crash Protection, Rinsed From Inside And Outside. 11. Reagent Inventory And Calculation Of Remaining Reagent Volume And Test Should Be Available. 12. Reaction Temperature 37c T 0.3. 13. Light Source- Halogen Tungsten Lamp. 14. Calibration Principle Should Be Linear, Factor, 2 Point, Point To Point, Spline, Log-logit And Exponential. 15. Assay Test - End Point, Kinetic, Biochromatic, Turbid Metric, Sample Blanking And Reagent Blanking And Ise (via Optional Integrated Ise Unit). 16. Reusable Pyrex Cuvette With Minimum Volume Of 180 I, Maximum Volume Of 500 I With 8 Stage Cuvette Washing System. 171 Inbuilt Automatic Qc And Automatic Calibration. Daily, Monthly Batch Qc With Data Archiving. 17. Complete Pc Along With Easy To Operate Software Should Be Provided With The Analyzer With The Storage Of > 20, 000 Patients Report With Starch Facility. I8. Input Voltage 100 To 240 Vac. 19. Power Consumption
Quantity : 03 Unit
Tender Value : 12 Lakhs
EMD : 12,000
Document Fees : 2,500
Authority Type : Medical Institutes
Notice Type : Domestic Tender Notice
Product / Services :Semi Auto Analyser
Doc Sale Starts : 29-Apr-2019
Doc Submit Before : 04-Jun-2019
Due Date : 07-Jun-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply And Commissioning Of Auto Analyzer At Kolkata

25-Apr-2019 Kolkata West Bengal
Tenders Are Invited For Supply And Commissioning Of Auto Analyzer ( No. Of Wells Run Per Assay ( Photo Metric Test Throughput (no. Of Tests) Per Hour 600 Or More, Capacity Of Loading Samples At A Time 50 Or More Sample Volume In l (2 To 60) Or More, On Board Assay Capacity 40 Or More, On Board Reagent Bottle Storage In Refrigerated Chamber 50 Or More, Number Of Reagent Probes For Picking Up Reagent Separately 2 Or More, Number Of Available Wavelength Ranging From 290 To 700 Nm Or More 10 Or More, Data Storage ( Patient Test, Qc Test & Calibration Data) 50, 000 Or More ) At Kolkata
Quantity : 2 Unit
EMD : 2.50 Lakhs
Authority Type : State Govt
Notice Type : Domestic Tender Notice
Product / Services :Semi Auto Analyser
Doc Sale Starts : 12-Oct-2018
Doc Submit Before : 20-May-2019
Due Date : 22-May-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Semi - Automated Biochemistry Analyzer At Kharagpur

15-May-2019 Kharagpur West Bengal
Tenders Are Invited For Supply Of Semi - Automated Biochemistry Analyzer ( Should Be Microprocessor Controlled General Purpose Bi-chromatic Photometer System With At Least 6 Filters Ranging From 340 To 630nm. Self Monitoring Built-in Incubation Systems For Temperature Controlled Absorbance Reading (37 Degree) Light Source : Tungsten/ Halogen Or Higher Grade With One Additional Bulb. Should Have End Point, Kinetic And Two Point Kinetic Measurement Modes. Should Have Flow Cell With Air Bubble Gap (patient Protected). Should Have Inbuilt Printer Or External Printer To Be Supplied. Should Have A Measurement Range From 0.001 To 2.300Abs Should Have A Full Size Display With On Screen Curve Should Have Quality Control Two Control/test QC Survey Of At Least 30 Points, Levy Jenny Plot. Should Have A Filter Half Bandwidth Of 10nm Or Lesser. Open System All Filters Conforming To The Kits Commonly Available In The Market Should Have 12 Position Filter Wheel Should Have A Test Programed Memory Of 100 Results Should Be Provided With Sample Carry Over Prevention Facility. Test Parameter Should Be Downloaded Via Rs232 And 12. Software Upgrades Via Rs232 With Availability Of Host Protocol Aspiration Should Be Based On Bellow/Peristaltic Pump/ Vacuum Pump. Should Provide 500 Ml Of Reagents For Urea, S. Creatine, S. Bilirubin, Sugar, Cholesterol, And Quality Control 5ml One Each For Normal, Abnormal. Should Be Supplied With On Line Pure Sine Wave UPS Of Sufficient Capacity For A Minimum Back Of 30 Minutes. Should Be Provided With Calibration Certificate Issued By The Manufacturer At The Time Of Installation And Periodic Calibration Must Be Done During Warranty / AMC Period. It Must Be UF - FDA Certified. Should Have Low Consumption Of Reagents Flow Cell Volume Is Only 25 Micro Litre Should Have Reread Facility For End Point Reactions Without Using Extra Reagents To See The Reproducibility ) At Kharagpur
Quantity : 1 Unit
EMD : 6,000
Notice Type : Domestic Tender Notice
Product / Services :Semi Auto Analyser, Biochemistry Analyzer
Doc Submit Before : 22-May-2019
Due Date : 22-May-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Fully Automated Random Access Biochemistry Analyser At Noida

15-May-2019 Noida Uttar Pradesh
Tenders Are Invited For Supply Of Fully Automated Random Access Biochemistry Analyser ( System: Floor Model, Discreet, Multi-channel, Random Access. The System Should Have The Facility Of Auto Predilution And Auto Rerun Of Samples. The Auto Analyzer Must Be A Random Access Analyzer With The Facility Of Continuous Loading Of Samples As Well As Reagents, Without Halting The System. Through Put: 130 Test / Hour Without Ise. Assay Modes: End Point, Rate, Fixed Point And Ise. Sample Loading: Minimum Of 80 Sample Positions With 30 Priority Positions (continuous Loading). Bar Code Reading Facility For Positive Sample Identification, Real Time Test Requisition Downloading From Host Should Be Possible. Cooled Compartment For Standards And Controls. Sample Cups: Primary And Secondary Tubes Along With Paediatric Cups With 50 l Dead Volume. Sample Types: Plasma, Urine, Serum, Csf, Hemolysate And Whole Blood For Hba1c Stat Facility: At Least 25 Sample Positions Must Be There In The System. The System Should Have Preferential Treatment For Stat And Paediatric Sample With The Facility Of Assigning All Positions As Stat Positions If Required Sample Volume: Sample Volume Typically Should Be Between 1 - 30 l Per Test, Programmable In Steps Of 0.1 l. Sample Probe: The System May Be A Single Probe System Operated By Separate Double Syringes To Minimize The Carryover. Probe Liquid Level Sensor, Sample Clot Detection And Crash Prevention Facility Should Be Available. The Aspiration Needle Should Be Multifunctional With Liquid Level Sensor, Collision Protector And With Integrated Mixer. Reagent Disk: Facility Of Using 3 Reagent System R1, R2, R3 Is A Must And Any Position Should Be Assigned With R1, R2 And R3 The Instrument Must Have At Least 30 Reagent Positions With A Facility Of Using 10, 25 And 50 Ml Of Reagent Bottles To Minimize The Reagents Wastage. The System Should Have Semi Disposable Reaction Rotor Comprising Of At Least 45 Reusable Cuvettes With Long Life. Etc. ) At Noida
Quantity : 1 Unit
EMD : 1 Lakhs
Notice Type : Domestic Tender Notice
Product / Services :Biochemistry Analyzer
Doc Submit Before : 22-May-2019
Due Date : 22-May-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information