Supply Of Fluorescence Plate Reader At Faridabad, Haryana

Microplate Reader Tender Posted on :  28 Feb, 2015
Tender Details:

supply of fluorescence plate reader

  • EMD

    :

    Rs. 50000/-

  • Document Fees

    :

    Rs. 1,000/-

  • Quantity

    :

    01 Unit

  • Notice Type

    :

    Domestic Tender Notice

  • Products

    :

    Microplate Reader

View Similar Tenders
Participation in above Tender has been closed. View more Tenders below, or click the button above for Similar Tenders.
Important Dates

  • Tender Publish Date

    :

    2015-02-28

  • Document Submit Before

    :

    2015-03-16

  • Tender Due Date

    :

    2015-03-16

TENDER ALREADY EXPIRED

Faridabad - Haryana

  • Authority Name:Regional Center For Biotechnology
  • Address:Biotech Science Cluster, Gurgaon-faridabad Expressway 3rd Milestone Towards Gurgaon, Village-bhankri, District-faridabad-121001, Haryana, Faridabad - Haryana

» Recommended Tenders for Microplate Reader

Supply And Installation Of Multimode Micro-plate Reader At Kolkata

20-Mar-2019 Kolkata West Bengal
Tenders Are Invited For Supply And Installation Of Multimode Micro-plate Reader ( 1 The Instrument Should Be A Spectral Scanning Multimode Microplate Reader Capable Of Doing Photometry, Fluorometric Intensity, Luminometry, Time-resolved Fluorescence And Upgradable To Fluorescence Polarization, Western Blot Applications. 2 All Specifications Of The System Should Be Tested And Guaranteed. The Specification Should Not Be Typical Or Relative Values. 3 The Quoted Instrument Should Have Option For Dual Dispensers For Flash Luminescence Assays Like Ca2+ Flux , Atp Assays Etc. 4 Onboard Incubator And Shaker Should Be Available. Incubation Temperature Should Be Upto 450c And Orbital Shaker With Adjustable Speed And Diameter. Optical System: 1 Instrument Should Have Monochromator Based, Double Excitation And Double Emission Monochromators For Fluorescence Applications. 2 Instrument Should Have Double Monochromators For Photometric (uv And Vis) Measurement. 3 The Instrument Should Have A Single Lamp Source And Separate Detectors For Photometry, Fluorometry, Time Resolved Fluorescence And Luminescence. 4 Instrument Should Automatically Calibrate Results With Different Gain Settings To Obtain Single Consistent Measurement Range. Absorbance / Photometry 1 Measurement Range In Photometry: 200-1000nm 2 Linear Measurement Range In Photometry: 0-4abs At 450 Nm, 2% (96-well Plate) 3 Instrument Should Have On-board Pathlength Correction For Direct Quantification. E.g. Nucleic Acids And Proteins. 4 Plate Type : 6 Well To 1536 Well Format ) At Kolkata
EMD : 66,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Sale Starts : 20-Mar-2019
Doc Sale Ends : 02-Apr-2019
Doc Submit Before : 02-Apr-2019
Due Date : 04-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of SNP-Multi-Mode Microplate Reader At Sabour

13-Mar-2019 Sabour Bihar
Tenders Are Invited For Supply Of SNP-Multi-Mode Microplate Reader ( 1. UV/Vis Absorbance And Fluorescence Technology To Support Different Assays. 2. System Must Be Capable Of Measuring End-point Assays, Kinetics Capability, Spectrum And Well-area Scanning. 3. Instrument Should Be Using Different PMTs As Detectors For Abs And Fluorescence 4. Plate Formats: 6- To 384 Well 5. Light Source: Xenon Flash Lamp 6. Linear/Orbital And Double Orbital Shaking Modes Are Required 7. Temp Control: Temperature Range From 3 C Above Ambient Up To 50 C Or Better 8. Preferably The Instrument Should Have Movable Detectors/plate Height Sensor For Optimization And Standardization Of The Assays. 9. Instrument Throughput Time/Read Time A) Absorbance ---43 Sec Or Better (96-well), 1 Min 30 Sec Or Better (384-well) B) Fluorescence--- 1 Min 4 Sec Or Better (96-well), 2 Min 40 Sec Or Better (384-well) 10. Instrument Sensitivity ) At Sabour
EMD : 50,000
Document Fees : 1,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Submit Before : 29-Mar-2019
Due Date : 30-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Elisa Cum Multifarious Micro Plate Reader At Gwalior

07-Mar-2019 Gwalior Madhya Pradesh
Tenders Are Invited For Supply Of Elisa Cum Multifarious Micro Plate Reader ( Filter Based Elisa Reader With Halogen Lamp As Light Source And Silicon Photo Detectors. Linear Measurement Range Of 0 To 6 Abs. Wavelength Range From 340 To 850 Nm. Photometric Accuracy Of 2 % Or Better. Resolution Of 0.001abs. Variable Speed Plate Shaking Capability In 3 Different Modes. Easy Access 8 Position Filter Wheel. Machine Should Be Supplied With 3 Standard Filters Of 405nm, 450nm And 620nm. Should Have Automatic Filter Selection Option. Should Have Automatic Calibration Before Each Reading. Should Able To Read 96 Well Format. Capable Of Doing Multi Standard Tests And Controls. Should Be Capable Of Reading Uv And Flat Type Wells. Able To Run Both In Stand-alone Mode And With Computer & Software Controlled. System Should Have Usb Port For External Printer Connectivity Option For The Data Printout. Unlimited User License To Analyze The Data In Different User / Computer Systems . ) At Gwalior
EMD : 26,000
Document Fees : 2,000
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Sale Starts : 06-Mar-2019
Doc Submit Before : 28-Mar-2019
Due Date : 29-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Multimode Microplate Reader At Kolkata

12-Mar-2019 Kolkata West Bengal
Tenders Are Invited For Supply Of Multimode Microplate Reader ( Multimode Microplate Reader Specifications: General: 1 Multimode Microplate Reader System For Absorbance (uv/visible) & Filter-based Detection For Reading Fluorescence (top & Bottom). Luminescence (top & Bottom), Fp (top & Bottom) & Trf(top & Bottom) Assays. 2 System Should Be Capable Of Handling 6 To 1536 Well Plate Format 3 The System Should Incorporate A Dynamic Filter Wheel Or Slide System Or Cube System, With Space For Storage/use Filters At Least 16 Filters Or More At A Time. 4 System Should Be Having Pre-fitted Customized Filters 5 System Should Be Capable Of At Least Linear And Orbital Plate Absorbance: 6 Wavelength Selection: Minimum 230 Nm 999 Nm (1.0 Nm Increments). 7 System Should Have Spectrometer For Wavelength Flexibility 8 Detector: Silicon Photodiode Or Ccd Fluorescence (Filter Based) 1 System Should Be Capable Of Top And Bottom Detection 2 Wavelength Range: Minimum Range 250 Nm 700 Nm 3 At Least 4 Sets (8nos) Of Fluorescence Filters To Be Included ) At Kolkata
EMD : 10,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader, Inverted Microscope, Freeze Dryers
Doc Sale Starts : 11-Mar-2019
Doc Sale Ends : 08-Apr-2019
Doc Submit Before : 08-Apr-2019
Due Date : 10-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply And Installation Of Multi Plate Reader At Prayagraj

23-Mar-2019 Prayagraj Uttar Pradesh
Tenders Are Invited For Supply And Installation Of Multi Plate Reader ( Detection Method, Absorbance, Fluorescence Intensity (top &bottom), Luminescence And Time Resolved Fluorescence (TRF), Reading Modes: End Point, Kinetic, Spectral Scanning, Well Area Scanning And Alpha Lisa Detection, Range: All Modes Are Monochromator Based, Absorbance: 250 900nm (Monochromator With 1nm Increment), Resolution 0.0001 OD Or Better, Fluorescence Intensity: 250 850nm (Double Grating Monochromator Top And Bottom Optics 1nm Increment), Dynamic Range: 6 Decades Or More, Sensitivity: Top:
Quantity : 1 Unit
Tender Value : 18 Lakhs
EMD : 45,000
Authority Type : Technical Institutes
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Sale Starts : 09-Mar-2019
Doc Sale Ends : 28-Mar-2019
Doc Submit Before : 28-Mar-2019
Due Date : 29-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Multi Plate Reader At Prayagraj

16-Mar-2019 Prayagraj Uttar Pradesh
Tenders Are Invited For Supply Of Multi Plate Reader ( Detection Method :: Absorbance, Fluorescence Intensity (top &bottom), Luminescence And Time Resolved Fluorescence (TRF) Reading Modes: End Point, Kinetic, Spectral Scanning, Well Area Scanning And Alpha Lisa Detection Range: All Modes Are Monochromator Based Absorbance: 250 900nm (Monochromator With 1nm Increment), Resolution 0.0001 OD Or Better Fluorescence Intensity: 250 850nm (Double Grating Monochromator Top And Bottom Optics 1nm Increment), Dynamic Range: 6 Decades Or More, Sensitivity: Top:
Quantity : 1 Unit
EMD : 45,000
Authority Type : Technical Institutes
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Submit Before : 28-Mar-2019
Due Date : 29-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Multimode Reader At Bhagalpur

13-Mar-2019 Bhagalpur Bihar
Tenders Are Invited For Supply Of Multimode Reader ( Detection Modes: Uv-vis Absorbance, Fluorescence Intensity, Luminescence Read Methods: Endpoint, Kinetic, Area Scanning, Absorbance Spectral Scanning. Microplate Types: 6 To 384-wells. Shaking Mode: Should Have Linear, Orbital, Double Orbital. Data Analysis Software Should Be Supplied With The Instrument. Absorbance : Light Source: Xenon Flash Detector: Pmt (photodiode) Wavelength Selection: Monochromator Wavelength Range: 200 Nm To 999 Nm, In 1 Nm Increments Monochromator .Bandwidth: < 5 Nm Dynamic Range: 0 To 4.000 Od Resolution: 0.0001 Od Monochromator .Wavelength Accuracy: + 2 Nm Monochromator Wavelength Repeatability: + 0.2 Nm (standard Deviation) Reading Speed (kinetic): 96 Wells: 12 Seconds; 384 Wells: 23 Seconds Fluorescence Intensity: Light Source: Halogen Detector: Pmt Wavelength Range: 200-800 Nm (low Noise ). Dynamic Range:7decades Sensitivity: Fluorescein 2 Pm Reading Speed (kinetic): 96 Wells: 24 Secs; 384 Wells: 76 Secs Luminescence : Wavelength Range: 200 700 Nm Dynamic Range: 7 Decades Sensitivity: 10 Amol ATP. Should Have USB Port For Computer Control. Suitable Computer And UPS. The Instrument Should Have 1 Years Warranty From The Date Of Installation. It Should Also Be Compatible To Read 2l Low Volume 12icroplate With 16 Samples. Onsite Training/demo At Time Of Demand. Power: 100 240 Volts AC 50/60 Hz, CE , TUV & IVD Marked . ) At Bhagalpur
EMD : 26,000
Document Fees : 1,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Doc Submit Before : 01-Apr-2019
Due Date : 02-Apr-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Multimode Reader At Chandigarh

20-Feb-2019 Chandigarh Chandigarh
Tenders Are Invited For Supply Of Multimode Reader At Chandigarh
Quantity : 1 Unit
EMD : 30,000
Document Fees : 200
Notice Type : Domestic Tender Notice
Product / Services :Microplate Reader
Due Date : 28-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Deep Freezer And Cold Cabinet At New Delhi

14-Mar-2019 New Delhi Delhi
Tenders Are Invited For Supply Of Deep Freezer And Cold Cabinet ( 1. Deep Freezer (-20 Degree) 01 No. 2 Should Have A Capacity Of Minimum 344 Liters 3 Should Be An Upright Model. 4 Should Have Temperature Range Of -17c To -24 c 5 Should Have A Digital Microprocessor Temperature Controller Allowing For The Precise Temperature Management Necessary For Critical Samples And Reagents. 6 Should Have Alarms For Open Door, Power Failure And High/low Temperature Fluctuations. 2 Cold Cabinet 01 No. 1 Should Have A Capacity Of 300-400 Liters 2 Should Have Adjusting Temperature Range Of 0c - 10 c 3 Should Have A Glass Door For Clear Visibility 4 Should Have Powerful Insulation To Ensure Maximum Temperature Stability During Power Loss. 5 Should Have Cabinet Illumination With The Help Of Led Or Fluorescence Lights. 6 Should Have Wheels For Easy Movement) At New Delhi
Tender Value : 13.25 Lakhs
EMD : 30,000
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Deep Freezer, Cold Room Cabinets, Microplate Reader, Laboratory Shakers
Doc Sale Starts : 02-Mar-2019
Doc Sale Ends : 23-Mar-2019
Doc Submit Before : 23-Mar-2019
Due Date : 25-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information

Supply Of Minor Equipment - Spectrophotometer At Nadia

02-Mar-2019 Nadia West Bengal
Tenders Are Invited For Supply Of Minor Equipment - Spectrophotometer ( 1. Spectrophotometer (Single Beam) (Item Code No. 18) - 190-800nm, Range Optical System Not Less Than 12, 000 Lines/ Mm, Accu + 1 Nm, Tungsten & Deuterium Lamps Automataic Scanning Equipment, With USB Port To Connect To Computer, 1 Personal Computer, 2 Sets Glass Cuvette+2 Sets Quartz Cuvette Qty 1 Unit 2 Spectrophotometer (Double Beam) (Item Code No. 19) 190-800nm, Range Optical System Not Less Than 12, 000 Lines/ Mm, Accu + 1 Nm, Tungsten & Deuterium Lamps Automatic Scanning Equipment, With USB Port To Connect To Computer, Temperature Control, 0-90C. Qty 1 Unit 3 Microplate Absorbance Reader (Item Code No. 35) Wavelength Range, Nm : 400750, Number Of Filters Accommodated : 8, Provide Filter: (415, 450, 490, 595, 655, And 750 Nm Filters), The Instrument Can Read Flat-, U-, Or V-bottom Microplates Or 8- Or 12-well Strip Plates On Board Software, Automatic Control Of Detection, Data Formats, And Analyses, Proactive And Prompt Maintenance, Accommodation Of Various Validation Protocols Including Installation Qualification And Operational Qualification (IQ/OQ) Software, Built-in (64 Assay Protocols, Data Storage, Analysis, And Reports); Computer Controlled, (Microplate Manager 6, PC And Mac, Format Readings, Analyze Data, Kinetic And Single Point), Printer : Built-in, Shaker : Three Speed Qty 1 Unit 4. UV-Vis Spectrophotometer (Item Code No. 184) I) Optical Systems: Single Beam, Modified Czerny-Turner Monochromator Geometry For Better Aberration Correction With Holographic Grating Of 1200 Lines / Mm, Blazed At 250 Nm. Ii) Wavelength: A) Range: 200-1100 Nm; B) Resolution: 0.1 Nm; C) Accuracy: 1 Nm; D) Repeatability: 0.5nm; E) Bandwidth: 2 Nm Iii) Photometric: A) Accuracy: 0.005 Abs At 1A; B) Range: 0-2.5 Abs; C) Repeatability: 0.002 Abs At 1A; Drift: 0.003 Abs/hr (after 1 Hr Warm-ups At 500 Nm) Iv) Stray Light: < 0.1% T At 220 Nm & 370 Nm V) Base Line: A) Correction: Auto; B) Flatness: 0.003 Abs / Hr (after 40 Mins Warm-ups) Vi) Modes Of Operation: A) Single Wavelength & Multi Wavelength; B) Spectrum Scan; C) Time Scan Vii) Modes Of Measurement: A) % Transmittance; B) Absorbance; C) Concentration By K-factor And Multistandards. Vii) Data Processing: A) Stand Alone; B) Peak-Pick; C) Spectrum Printout Qty 1 Unit At Nadia
Authority Type : Institute/University
Notice Type : Domestic Tender Notice
Product / Services :Spectrophotometer, UV-VIS Spectrophotometer, Microplate Reader, Binocular Microscope
Doc Sale Starts : 02-Mar-2019
Doc Sale Ends : 22-Mar-2019
Doc Submit Before : 22-Mar-2019
Due Date : 25-Mar-2019
Additional Details Available on Purchase:
Authority Details Contact Info Publication Document

View Tender Information